Filter events πŸš€

In order to enhance focus on critical tasks and reduce unnecessary data processing within Data One (i.e. Data Mover in a bundle with Data Watcher), specific events that should not be transmitted can be filtered.

This can be achieved by configuring a particular property designed to selectively prevent the forwarding of events associated with designated service tasks to Data Mover and Watcher.

Follow these steps to set up event filtering:

  1. In Data One, go to Setup β†’ Advanced Settings.

  2. Click on the NEW button in the top-right corner of the screen.

  3. Enable the Click to add a new module/section toggle.

  4. In the Module field, enter workflow.

  5. In the Section field, enter logging.

  6. In the Property Name field, type workflow.logging.hide.dw.event.

  7. In the Property Value field, enter the list of the service tasks that should not be sent to Data Watcher, separated by a semicolon (;). Here is an example: bpmEventNotificationService;bpmGetMetadataService;bpmSetGenericMetadataService;bpmVirtualPathFromString;bpmVirtualPathToString

  8. Click CONFIRM to save.

The new property will be applied immediately. You do not need to restart the CEMAN.

Last updated